Step 1 | Open the SAP task to which you want to add the parameter. |
---|---|
Step 2 | Click the Job Steps tab. The Job Steps list displays a list of all Job Steps for which values have been defined for this task. |
Step 3 | Click the |
Step 4Step 5 | Enter/select Details for a new Job Step, using the field descriptions below as a guide. Fields with the are Options Fields that allow you to populate their drop-down lists with options retrieved from the SAP system. |
Step 6 | Click the button. |
Job Step Details Field Descriptions Descriptions
Field Name | Description |
---|---|
Type | Read only; Job step type. |
Program Name | Name of the ABAP program to be processed in the background. |
Variant Name | Variant to use to process the report. |
Execution Language | Specifies the language in which the system executes and prints the output. |
SAP User Name | User name in the SAP system. |
Print Parameters... | The Print Parameters... button opens a dialog that allows you to set up print parameters. |
Output Device | Specifies the printer or fax machine. Populate the drop-down list with options retrieved from the SAP system by clicking the refresh picker icon next to its drop-down list to display a Refresh Output Device Options... dialog. The fields on the Refresh Output Device Options... dialog are fields from the SAP Task Details, and the values for those fields in the dialog are, by default, the same as the values for the fields in the Details. You can keep the current values or change them from their drop-down lists. |
Number of Copies | Number of printouts. |
Page Area | Specifies if everything should be printed or select pages. Options are:
|
Page From | If Page Area = Page, first page in the range of pages to be printed. |
Page To | If Page Area = Page, last page in the range of pages to be printed. |
Print Time | Specifies when the spool request will be sent to the output device. Options are:
|
Use Temporary Variant | Specification for whether or not to use Temporary Variant. |
Temporary Variant | If Use Temporary Variant is enabled, Allows you to enter temporary variants needed by the program to run. To add a temporary variant, click the + icon and enter a Name, Type, Lower Limit/Single Value, Upper Limit, Option and Sign. To delete a variant, select in the list of variables and click the - icon. |
...