Universal Automation Center Agent
----
UAG1120E UAG1120I A Primary agent with system ID 'sid' is already running.
...
A Primary agent is already running with the same system identifier. Only one Sysplex Primary agent can be active for each system identifier.
Severity
ErrorInformational
System ActionThe
program terminatesDepending on the configuration, the agent will either start as a Secondary agent, or the agent might shut down.
User Action
If this condition is expected, nothing. If the intention is to run another agent, configure each one with a unique system identifier. Else, configure this agent to run as a Secondary agent.
...
Refresh of the Extension Manager has finished.
Severity
Informational
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1126I This Agent will start as a Secondary.
Description
A Primary agent is already running with the same system identifier. Since this agent is configured as Primary/Secondary, it will start as a Secondary agent.
Severity
Informational
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1127I This Agent will request to take over as Primary.
Description
A Primary agent is already running with the same system identifier. Since this agent is configured as Always Primary, it will request to take over as Primary agent.
Severity
Informational
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1128W Request to take over as Primary declined.
Description
Another agent has requested to take over as Primary agent. Since this agent is configured as Always Primary, the request has been declined.
Severity
Warning
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1129E Unable to take over as Primary agent. Agent is shutting down.
Description
This agent had requested to take over as Primary agent. The request has been declined by the current Primary agent.
Severity
Error
System Action
This agent will shut down.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1130I Agent on system system requests this agent to switch to Secondary.
Description
This agent has been requested to switch to Secondary mode by the agent on the indicated system.
Severity
Informational
System Action
This agent will switch to Secondary mode.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1131W WARNING: Agent name is connected with a mismatched system ID of ID.
Description
An agent is connected to the XCF structure being used by this agent. The agent is using a different system ID from this agent. This will create issues with tracking workload in the Sysplex.
Severity
Warning
System Action
Processing continues.
User Action
Update the configuration to prevent agents with different system IDs connecting to the same XCF structure.
Component
Universal Automation Center Agent
----
UAG1132E Error formatting the JCL to execute UFTP (errno): reason
Description
The JCL needed to execute the Universal Agent FTP client, UFTP, on behalf of a File Transfer or Remote File Monitor task could not be generated. errno is the error number and reason is an explanation of the error.
Severity
Error
System Action
The File Transfer or Remote File Monitor task will fail to execute.
User Action
Examine the JCL submitted to JES to identify which statement failed toget formatted properly. If possible, change the values specified on the task form to correct the formatting error. Otherwise, contact Stonebranch customer support for assistance.
Component
Universal Automation Center Agent