When issued against a Secondary agent | This command behaves like the STOP console command. |
When issued against a Primary agent | This command shuts down the Broker (and agent) while controlling the Sysplex failover behaviour: |
When issued without the FAILOVER or NOFAILOVER parameter | Failover will behave as configured by the automatic_failover parameter in UAGCFG00. |
When FAILOVER Is specified | An available Secondary agent will take over as Primary, regardless of how failover is configured. When the optional < |
When NOFAILOVER Is specified | No Secondary agent will take over as Primary, regardless of how failover is configured. |
...