When issued against a Secondary agent | This command behaves like the z/OS STOP command (P <ubroker>). |
When issued against a Primary agent | This command shuts down the Broker (and agent) while controlling the Sysplex failover behaviour: |
When issued without the FAILOVER or NOFAILOVER parameter | Failover will behave as configured by the automatic_failover parameter in UAGCFG00. |
When FAILOVER Is specified | An available Secondary agent will take over as Primary, regardless of how failover is configured. When the optional < |
When NOFAILOVER Is specified | No Secondary agent will take over as Primary, regardless of how failover is configured. |
...
The Universal Broker reads in the UACL entries when the program is started. If the UACL file is changed, the new entries can be activated by recycling the Broker or by sending the Universal Broker a Universal Control REFRESH command that will instruct the Universal Broker to reread all its configuration files including the UACL file.
...