EVENT_STATE - UEM Manager configuration option

Description

The EVENT_STATE option marks the beginning of a set of command line options that describes UEM Server's response to an event that enters the specified state.

When this option is used, a corresponding HANDLER_ID, USER_COMMAND, or USER_SCRIPT option also must be provided.

There are three different event states:

  • Triggered
    An occurrence of a monitored event was completed.
  • Rejected
    An occurrence of a monitored event was detected, but failed to complete before the date and time specified by the event's INACTIVE_DATE_TIME elapsed.
  • Expired
    Date and time specified by an event's INACTIVE_DATE_TIME elapsed, with no occurrence of the monitored event detected.

The UEM Server may repeat the action it takes in response to Triggered and Rejected events if the Server detects more than one occurrence of a monitored event.

By definition, there are no event occurrences for an Expired event. UEM Server executes actions in response to such events just once.

Usage

Method

Syntax

IBM i

HP NonStop

UNIX

Windows

z/OS

Command Line, Short Form

n/a

Command Line, Long Form

-triggered | -rejected | -expired

(tick)

(tick)

(tick)

Environment Variable

n/a

Configuration File Keyword

n/a

Value

(There are no values for these parameters.)