/
BROKER_STATUS_ALERTS_AT_STARTUP - UEC configuration option
BROKER_STATUS_ALERTS_AT_STARTUP - UEC configuration option
Description
The BROKER_STATUS_ALERTS_AT_STARTUP option specifies whether or not UNV1059T alert messages (Broker responding) will be issued for initial Broker polls when Universal Enterprise Controller starts up.
Usage
Method | Syntax | IBM i | HP NonStop | UNIX | Windows | z/OS |
---|---|---|---|---|---|---|
Command Line, Short Form | n/a | |||||
Command Line, Long Form | n/a | |||||
Configuration File Keyword | broker_status_alerts_at_startup option |
Values
option is the specification for whether or not UNV1059T alert messages will be issued when Universal Enterprise Controller starts up.
Valid values for option are:
- yes
UNV1059T alert messages will be issued on the initial poll for Brokers that are responding. - no
UNV1059T alert messages will not be issued on the initial poll for Brokers that are responding.
In either case, UNV1056T alert messages (Unable to connect) will be issued on the initial poll for Brokers that are not responding.
Default is no.
, multiple selections available,
Related content
BROKER_STATUS_ALERTS_AT_STARTUP - UEC configuration option
BROKER_STATUS_ALERTS_AT_STARTUP - UEC configuration option
More like this
BROKER_STATUS_ALERTS_AT_STARTUP - UEC configuration option
BROKER_STATUS_ALERTS_AT_STARTUP - UEC configuration option
More like this
BROKER_STATUS_ALERTS_AT_STARTUP - UEC configuration option
BROKER_STATUS_ALERTS_AT_STARTUP - UEC configuration option
More like this
Starting and Stopping Universal Enterprise Controller - z/OS
Starting and Stopping Universal Enterprise Controller - z/OS
More like this
UEM_AUTOSTART - UBROKER Configuration Option
UEM_AUTOSTART - UBROKER Configuration Option
More like this
UEM_AUTOSTART - UBROKER Configuration Option
UEM_AUTOSTART - UBROKER Configuration Option
More like this