UNV0500-UNV0599

UNV0500-UNV0599

----

UNV0500E Either the 'cmd' or 'script' argument is required.


Description


Neither the -cmd nor the -script parameter was supplied to Universal Command Manager.


Severity


Error


System Action


The program terminates.


User Action


Add the -cmd parameter to specify the name of the process to execute on a remote system. If several commands need to be run, use the -script parameter to specify the name of a local script file that contains the list of commands.


Component

Universal Command


----

UNV0501E A COMMAND-ID value must be specified when the RESTART value is YES or AUTO.


Description


The RESTART option has been set to a value of YES or AUTO. These two values require a command identifier be specified by the manager to uniquely identify the job to reattach. In the case of AUTO, the manager only reattaches should it find a job with the same command ID executing, else it starts a new instance.

The RESTART configuration value may be specified in a configuration file or system registry for Unix and Windows, respectively.


Severity


Error


System Action


The program terminates.


User Action


Add the -cmdid parameter to the Universal Command Manager command options.


Component

Universal Command


----

UNV0502E Error receiving restart response: func, errno, reason


Description


Universal Command Manager was unable to receive a response to a RESTART message from Universal Broker. This error will also be displayed if the Broker rejected the message due to the state of the Universal Command Server. The Broker will also reject the request if no component was found with the specified command ID, or if the component has already accepted a restart request from another Manager. func is the name of the function in which the error occurred. errno is the error number. reason is an explanation of the error.


Severity


Error


System Action


If the Broker rejected the restart request due to the state of the Universal Command Server, the manager may re-send the request, depending on the Server's state. If the Broker rejected the request for some other reason, the restart request will not be re-sent. If the request can't be re-sent, or some other error occurred, the program will terminate. If the request can be re-sent, the Manager will continue to do so until the number of restart attempts exceeds the retry count in the Manager's configuration.


User Action


Examine the error messages to identify the reason the response is in error. Make sure a network connection is still available between the client and server machines. Check the Universal Broker message log for any errors reported by Universal Broker. If the problem persists, contact Stonebranch customer support.