UNV1000-UNV1099
----
UNV1000I Universal Enterprise Controller version started.
Description
Indicates successful startup of Universal Enterprise Controller. version specifies the program's version and build level.
Severity
Informational
System Action
None
User Action
None required.
Component
Universal Enterprise Controller
----
UNV1003W Broker at IP address ipaddr:port has reached its maximum number of components.
Description
The Broker at IP address ipaddr listening on port port is running its maximum number of components.
Severity
Warn
System Action
The program continues running.
User Action
This is an indication that the broker is fully utilized. If this condition continues the broker's workload should be analyzed.
Component
Universal Enterprise Controller
----
UNV1004E Error adding broker alert alertnum to broker name: func, reason.
Description
An error occurred adding alert number alertnum to broker name. The function func encountered an error as described by reason.
Severity
Error
System Action
The program continues running.
User Action
Contact Stonebranch Customer Support for assistance.
Component
Universal Enterprise Controller
----
UNV1006E Component configuration error in compName.
Description
An error occurred building a runtime definition for an installed component, identified by compName. This definition consists of configuration options used by Universal Enterprise Controller to manage components at runtime. If the problem is due to a system error, this message will be accompanied by UNV0214.
Severity
Error
System Action
The program terminates.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1007E Cannot access installation directory 'dir': reason
Description
The installation directory identified by dir could not be accessed. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Check the value of the installation_directory entry in the Universal Enterprise Controller configuration file. Make sure the directory exists and the user account running the controller program has sufficient access to that directory. Re-install Universal Enterprise Controller if necessary.
Component
Universal Enterprise Controller
----
UNV1008E Installation directory is not defined.
Description
The program could not find the installation_directory entry in the Universal Enterprise Controller configuration file, or the installation_directory entry has no value associated with it.
Severity
Error
System Action
The program terminates.
User Action
Make sure there is an installation_directory entry in the Universal Enterprise Controller configuration file. If the entry does not exist, add it. Set its value to the directory where Universal Enterprise Controller is installed. Reinstall the program if necessary.
Component
Universal Enterprise Controller
----
UNV1009E Cannot access nls directory 'dir': reason
Description
The nls directory, used to store message catalogs and text translation tables, could not be accessed. dir is the complete path name of the nls directory. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Make sure the directory exists and the user account running the program has access to this directory. If the directory does not exist, re-install the product.
Component
Universal Enterprise Controller
----
UNV1011E Error querying broker: name, addr(ip):port, step1, step2, func, reason.
Description
An error occurred querying broker named name for its status. The broker's defined TCP/IP host address is addr listening on port port. The processing steps that failed are step1:step2, in function func, for the reason reason.
Severity
Error
System Action
The program continues.
User Action
An error can occur for many reasons. Check for some of the following common problems. The broker host name is incorrect or the port number is wrong. The network connection is not available between the controller and the broker host. The broker host system was brought down. The broker program was brought down.
Component
Universal Enterprise Controller
----
UNV1014E func failed: (errno) reason
Description
A call to a system function, identified by func, was not successful. errno is the error number. reason is an explanation of the error.
Severity
Error
System Action
The action of the program depends on the context in which the error occurred.
User Action
Contact Stonebranch customer support if unable to identify and resolve the problem.
Component
Universal Enterprise Controller
----
UNV1015E Cannot access working directory 'dir': reason
Description
The working directory, whose entire path is specified by dir, could not be accessed. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Check the value of the working_directory entry in the Universal Enterprise Controller configuration file. Make sure that directory exists and that the user account running the controller program has sufficient access to that directory. If the directory does not exist, simply create it; re-installation should not be necessary.
Component
Universal Enterprise Controller
----
UNV1016E Cannot access log directory 'dir': reason
Description
The log directory, used to store messages issued by Universal Enterprise Controller, could not be accessed. dir is the complete path name of the log directory. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Make sure the directory exists and the user account running the program has write access to this directory. If the directory does not exist, simply create it; re-installation should not be necessary.
Component
Universal Enterprise Controller
----
UNV1018E Component definition compname is missing a command line specification.
Description
The start_command entry in the definition file for the component identified by compname could not be found.
Severity
Error
System Action
The program terminates.
User Action
Contact Stonebranch customer support to obtain the name of the process executed by the specified component.
Component
Universal Enterprise Controller
----
UNV1019E Error reading component definition directory 'dir': func, errno, reason
Description
An attempt by the controller program to access the component definition files failed. dir is the name of the directory from which the program tried to read the files. func is the name of the function in which the error occurred. errno is the error number. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Make sure the user account running the controller program has read access to the component definition directory. If there are no component definition files in that directory, re-install Universal Command. If the problem persists, contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1020E Component definition compname is missing a working directory specification.
Description
The working_directory entry in the definition file for the component identified by compname is either missing or has no value associated with it.
Severity
Error
System Action
The program terminates.
User Action
Make sure there is a working_directory entry in the component's definition file. If the entry does not exist, add it. Set its value to a directory where any output files generated by the component should be stored.
Windows NT/2000 users: This value can be set using the Component Definitions panel of the Universal Configuration Manager applet, accessible via the Control Panel.
Component
Universal Enterprise Controller
----
UNV1021E Cannot access component directory 'dir': reason
Description
The component definition directory identified by dir could not be accessed. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Check the value of the component_directory entry in the Universal Enterprise Controller configuration file. Make sure the directory exists and the user account running the controller program has read access to that directory. Re-install Universal Enterprise Controller if necessary.
Component
Universal Enterprise Controller
----
UNV1022E Error getting message msgid: func, errno, reason
Description
The command line help message with an ID of msgid could not be retrieved from the message catalog. func is the name of the function in which the error occurred. errno is the error number. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1023E Open failed for registry key 'key': reason
Description
The registry key specified by key could not be opened. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Make sure the specified registry key exists (using the registry editor, regedit.exe) and the user account running the controller program has read access to that key. If the key does not exist, repair the installation using Add/Remove Programs, which is accessible from the Control Panel. Select Universal Command from the list of programs. When the installation program begins, select the "Repair" option. If the problem persists, contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1025E Error iterating component key 'key': func, errno, reason
Description
A list of subkeys of the registry key specified by key could not be obtained. func is the name of the function that prompted the error. errno is the error number. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1027E Cannot access 'codepage' file 'file': reason
Description
The text translation file specified by file cannot be read. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Check to see if the specified file exists in the Universal Enterprise Controller's 'nls' directory. If it does exist, make sure the user account running the controller program has read access to that directory. If necessary, re-install Universal Enterprise Controller.
Component
Universal Enterprise Controller
----
UNV1028E Log file directory verification failed: dir, func, reason
Description
The user account running the controller program does not have sufficient access to the log file directory, specified by dir. func is the name of the function in which the error occurred. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Make sure the user account running the controller program has the authority to create and write to files in the directory specified by dir.
Component
Universal Enterprise Controller
----
UNV1029E Error starting Broker Monitor Service: func, reason
Description
An error occurred starting the Broker Monitor Service. The function func encountered an error described by reason.
Severity
Error
System Action
The program continues.
User Action
Additional error messages may have been written. Review all error message for the possible cause. Contact Stonebranch customer support for assistance.
Component
Universal Enterprise Controller
----
UNV1030E Error processing request for session sid: msg, tranid func, reason
Description
An error occurred processing a client request on session identifier sid. The request is identified by the message name msg and the transaction ID tranid. func encountered the error described by reason.
Severity
Error
System Action
The program continues.
User Action
Additional error messages may have been written. Review all error message for the possible cause. Contact Stonebranch customer support for assistance.
Component
Universal Enterprise Controller
----
UNV1031E Error processing file 'file': func, reason
Description
An error occurred processing file file. The error is described by reason.
Severity
Error
System Action
The system action depends on the context in which the error occurred.
User Action
Review the reason for the error. The file may not exists or the program does not have security access to the file.
Component
Universal Enterprise Controller
----
UNV1032E Interface initialization error: func, errno, reason
Description
An error occurred initializing resources for either the UEC network or the UEC local interface. func is the name of the function that prompted the error. errno is the error number. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
If the problem persists, contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1033E Session manager message send error: func, errno, reason
Description
The controller encountered an error sending a message to a client. func is the name of the function that prompted the error. errno is the error number. reason is an explanation of the error.
Severity
Error
System Action
The program continues.
User Action
If the problem persists, contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1034I Session sesid created for ipadr:port.
Description
A new client session has been created. The session identifier is sesid. The client connection was accepted from host IP address ipadr on port number port.
Severity
Informational
System Action
The program continues.
User Action
No action required.
Component
Universal Enterprise Controller
----
UNV1035E Session creation failed: func, errno, reason.
Description
An error occurred creating a client session. The function func encountered the error described by the error number errno and the error reason reason.
Severity
Error
System Action
The program continues, but the client session is destroyed.
User Action
Review all messages during this period of time to determine the cause of the error. Contact Stonebranch customer support for assistance.
Component
Universal Enterprise Controller
----
UNV1036W User authentication failed for user username after attempts attempts.
Description
The user username failed its password validation when attempting to login to the Controller. The number of attempts reached the maximum number permitted.
Severity
Warning
System Action
The client session is destroyed.
User Action
No action required. This may be an indication of someone attempting unauthorized access to the system.
Component
Universal Enterprise Controller
----
UNV1037I Session sesid destroyed.
Description
A client session has been destroyed. The session identifier is sesid. Session destruction occurs when the session is no longer needed. The destruction process releases session resources.
Severity
Informational
System Action
The program continues.
User Action
No action required.
Component
Universal Enterprise Controller
----
UNV1038E Session destruction failed for session sesid: func, errno, reason.
Description
An error occurred destroying a client session sesid. The function func encountered the error described by the error number errno and the error reason reason.
Severity
Error
System Action
The program continues.
User Action
Review all messages during this period of time to determine the cause of the error. Contact Stonebranch customer support for assistance.
Component
Universal Enterprise Controller
----
UNV1039E Error processing file 'file': func, reason
Description
An error occurred processing file file. The error is described by reason.
Severity
Error
System Action
The system action depends on the context in which the error occurred.
User Action
Review the reason for the error. The file may not have enough disk space to complete the operation.
Component
Universal Enterprise Controller
----
UNV1040E Invalid maximum number of login attempts. Set to number. Must be greater than zero.
Description
The value specified for the maximum number of login attempts a user can make before being disconnected by the controller is invalid. This value must be greater than zero.
Severity
Error
System Action
The program terminates.
User Action
Make sure the value is set to be greater than zero.
Component
Universal Enterprise Controller
----
UNV1041E Error accepting connection and creating client session: func, reason
Description
An error occurred accepting the network connection from a client or in creating the client's session. Function func failed with as error described by reason.
Severity
Error
System Action
The system continues executing.
User Action
Review the reason for the error. Contact Stonebranch technical support for assistance.
Component
Universal Enterprise Controller
----
UNV1042E Error reading and parsing session message: func, reason
Description
An error occurred reading and parsing a session message from a client. Function func failed with as error described by reason.
Severity
Error
System Action
The system continues executing. If the error is a network error, the client session is closed and destroyed.
User Action
Review the reason for the error. Contact Stonebranch technical support for assistance.
Component
Universal Enterprise Controller
----
UNV1043I Session sesid timed out due to inactivity.
Description
Client session sesid timed out due to no message activity between the client and the controller.
Severity
Informational
System Action
The system continues executing.
User Action
No action required.
Component
Universal Enterprise Controller
----
UNV1044E Session time out processing failed: func, reason
Description
Client session time out processing failed in function func due to an error as described by reason.
Severity
Error
System Action
The system continues executing.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1045E Service manager failed to dispatch message for session sesid: func, reason
Description
The service manager subsystem failed to dispatch a message for session identifier sesid. Function func encountered an error described by reason.
Severity
Error
System Action
The system continues executing.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1046E Failed to add service svcname to the service manager list.
Description
The service manager could not add a service to its list of services.
Severity
Error
System Action
Undefined
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1047E Failed to add service to service object list: func, reason.
Description
An error occurred in function func while adding a service to a service object list. The reason for the error is described by reason.
Severity
Error
System Action
Depends on the context in which the error occurred.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1048E Error parsing XML tag set tagset: func, reason.
Description
An error occurred in function func while parsing the XML tag set tagset. The reason for the error is described by reason.
Severity
Error
System Action
Depends on the context in which the error occurred.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1049E Unrecognized target message on session sid: msg.
Description
An unrecognized message was received from session identifier sid for object target. The message name is msg.
Severity
Error
System Action
The message is ignored.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1050E Cannot access trace directory 'dir': reason
Description
The trace directory could not be accessed. dir is the complete path name of the trace directory. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Make sure the directory exists and the user account running the program has access to this directory. If the directory does not exist, re-install the product.
Component
Universal Enterprise Controller
----
UNV1051E Trace file directory verification failed: dir, func, reason
Description
The user account running the program does not have sufficient access to the trace file directory, specified by dir. func is the name of the function in which the error occurred. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Make sure the user account running the program has the authority to create and write to files in the directory specified by dir.
Component
Universal Enterprise Controller
----
UNV1052E Log directory verification failed: dir, func, reason
Description
The user account running the program does not have sufficient access to the log directory, specified by dir. func is the name of the function in which the error occurred. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Make sure the user account running the program has the authority to create and write to files in the directory specified by dir.
Component
Universal Enterprise Controller
----
UNV1053I Universal Enterprise Controller version ended successfully.
Description
Indicates the successful end of the Universal Enterprise Controller program. version specifies the program's version and build level.
Severity
Informational
System Action
None
User Action
None required.
Component
Universal Enterprise Controller
----
UNV1054E Universal Enterprise Controller version ended unsuccessfully with exit code errno.
Description
Indicates that the Universal Enterprise Controller program ended abnormally. version specifies the program's version and build level. errno is the program's exit status.
Severity
Error
System Action
The program terminates, returning the status specified by errno.
User Action
If the problem persists, contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1055I Universal Enterprise Controller received a termination request. Starting shutdown.
Description
Indicates that the Universal Enterprise Controller program has received a shutdown request.
Severity
Information
System Action
The program begins its shutdown processing.
User Action
No action is required.
Component
Universal Enterprise Controller
----
UNV1056A Unable to connect to broker name: msg.
Description
This message is printed as an alert notification that the broker named name did not respond to a query request. msg provides the reason the broker could not be reached.
Severity
Alert
System Action
The program continues. The broker will be queried later and if it responds, an alert message will be issued to record the event.
User Action
No action is required.
Component
Universal Enterprise Controller
----
UNV1057A The component cmpname cmpid on broker 'bkrname' is disconnected.
Description
This message is printed as an alert notification that the component named cmpname running on broker bkrname has become disconnected from the manager that started it. The component ID is cmpid.
Severity
Alert
System Action
The program continues. Once the component's communication is reestablished with the broker, an alert message will be issued to record the event.
User Action
No action is required.
Component
Universal Enterprise Controller
----
UNV1058A The component cmpname cmpid on broker 'bkrname' is orphaned.
Description
This message is printed as an alert notification that the component named cmpname running on broker bkrname has become orphaned. A component becomes orphaned when the component's manager terminates. The component ID is cmpid.
Severity
Alert
System Action
The program continues. Once another manager adopts the component, an alert message will be issued to record the event.
User Action
No action is required.
Component
Universal Enterprise Controller
----
UNV1059A Broker 'name' is responding.
Description
This message is printed as an alert notification that the broker named name is now responding to query requests. This alert is printed when a broker that was not previously responding to query request starts responding.
Severity
Alert
System Action
The program continues.
User Action
No action is required.
Component
Universal Enterprise Controller
----
UNV1060A The component cmpname cmpid on broker 'bkrname' is reestablished.
Description
This message is printed as an alert notification that the component named cmpname running on broker bkrname has reestablished communication with its manager. The component ID is cmpid. This alert is printed when a previously disconnected or orphaned component reestablishes communication with a manager.
Severity
Alert
System Action
The program continues.
User Action
No action is required.
Component
Universal Enterprise Controller
----
UNV1061A The component cmpname cmpid on broker 'bkrname' is disconnected: mwid, meuid, mipaddr, mhostname, cmdid.
Description
This message is printed as an alert notification that the component named cmpname running on broker bkrname has become disconnected from the manager that started it. The component ID is cmpid. The mwid is the manager work id. The meuid is the manager user id. The mipaddr is the manager ip address. The mhostname is the manager host name. The cmdid is the component's command id.
Severity
Alert
System Action
The program continues. Once the component's communication is reestablished with the broker, an alert message will be issued to record the event.
User Action
No action is required.
Component
Universal Enterprise Controller
----
UNV1062A The component cmpname cmpid on broker 'bkrname' is orphaned: mwid, meuid, mipaddr, mhostname, cmdid.
Description
This message is printed as an alert notification that the component named cmpname running on broker bkrname has become orphaned. A component becomes orphaned when the component's manager terminates. The component ID is cmpid. The mwid is the manager work id. The meuid is the manager user id. The mipaddr is the manager ip address. The mhostname is the manager host name. The cmdid is the component's command id.
Severity
Alert
System Action
The program continues. Once another manager adopts the component, an alert message will be issued to record the event.
User Action
No action is required.
Component
Universal Enterprise Controller
----
UNV1063A The component cmpname cmpid on broker 'bkrname' is reestablished: mwid, meuid, mipaddr, mhostname, cmdid.
Description
This message is printed as an alert notification that the component named cmpname running on broker bkrname has reestablished communication with its manager. The component ID is cmpid. This alert is printed when a previously disconnected or orphaned component reestablishes communication with a manager. The mwid is the manager work id. The meuid is the manager user id. The mipaddr is the manager ip address. The mhostname is the manager host name. The cmdid is the component's command id.
Severity
Alert
System Action
The program continues.
User Action
No action is required.
Component
Universal Enterprise Controller
----
UNV1079E Error opening 'lang' message catalog in directory 'dir': reason
Description
The message catalog for the language specified by lang could not be opened. dir is the directory from which Universal Enterprise Controller tried to open the file. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
The name of the message catalog file is ussmcxxx.umc, where 'xxx' is an abbreviation for the language (e.g., English - eng). Make sure the required file exists in the specified directory, and that the user account running the controller program has the authority to read files in that directory. Re-install the program if necessary.
Component
Universal Enterprise Controller
----
UNV1080E Error opening message destination: reason
Description
Universal Enterprise Controller was unable to set a destination for the messages it displays. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
If the destination is set to LOGFILE, make sure the user account running the controller program has write permissions to the log directory. Also, make sure there is sufficient space available on the system on which Universal Enterprise Controller is running.
Component
Universal Enterprise Controller
----
UNV1081E Network initialization failed: func, reason
Description
The Windows TCP/IP interface could not be started. func is the name of the function in which the error occurred. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Check with your network administrator to make sure TCP/IP is installed and properly configured on the system on which Universal Enterprise Controller will run. If the problem persists, contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1082E Failed to instantiate class class in func
Description
The class named could not be instantiated. class is the name of the class that could not be instantiate. func is the name of the function in which the error occurred.
Severity
Error
System Action
The program terminates.
User Action
Check that your system is not low on memory. If the problem persists, contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1083E Failed to load or create the user list: func, reason
Description
The user list could not be loaded. An effort to create a new user list has failed.
Severity
Error
System Action
The program terminates.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1084E Failed to load or create the broker list: func, reason
Description
The broker list could not be loaded. An effort to create a new broker list has failed.
Severity
Error
System Action
The program terminates.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1085E Failed to load or create the group list: func, reason
Description
The group list could not be loaded. An effort to create a new group list has failed.
Severity
Error
System Action
The program terminates.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1086E Failed to establish event handlers
Description
The event handlers could not be established for Universal Enterprise Controller.
Severity
Error
System Action
The program terminates.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1087E Service object pointer cannot be NULL
Description
The application tried to register a NULL service object with the service manager.
Severity
Error
System Action
Undefined
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1088E Service object failed during initialization
Description
The service object failed to initialize correctly.
Severity
Error
System Action
Undefined
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1089E Failed to retrieve service pointer from service object
Description
The controller failed to retrieve the address of a service from a service object.
Severity
Error
System Action
Undefined
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1090E Failed to add service to the service list
Description
The service manager could not add a service to its list of services.
Severity
Error
System Action
Undefined
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1091I service service successfully installed
Description
The service named was successfully installed.
Severity
Information
System Action
The program continues.
User Action
None required.
Component
Universal Enterprise Controller
----
UNV1092E Failed to register the service name service object
Description
The specified service object failed to register
Severity
Error
System Action
Universal Enterprise Controller terminates.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1093E Failed to start the session manager
Description
The controller's session manager failed to start.
Severity
Error
System Action
Universal Enterprise Controller terminates.
User Action
Contact Stonebranch customer support.
Component
Universal Enterprise Controller
----
UNV1094E Failed to re-allocated list: func, reason
Description
The Enterprise Controller was unable to resize a block of memory it uses. func is the name of the function in which the error occurred. reason is an explanation of the error.
Severity
Error
System Action
The program can usually continue running.
User Action
Check your machine's resource to see if it is low on memory or disk space.
Component
Universal Enterprise Controller
----
UNV1095E Failed to create a Broker Monitor thread: func, reason
Description
An error occurred creating a Broker Monitor thread. The function that failed is func. The reason it failed is reason.
Severity
Error
System Action
The program can usually continue running.
User Action
Check your machine's resource to see if it is low on memory or disk space.
Component
Universal Enterprise Controller
----
UNV1096E Critical section failure: func.
Description
An error occurred with a critical section. The function encountering the error was func.
Severity
Error
System Action
Program action depends on the context in which the error occurred. Refer to additional messages for the system action taken.
User Action
User action depends on the context in which the error occurred. Refer to additional messages for the recommended user action taken.
Component
Universal Enterprise Controller
----
UNV1097E Shutting down due to thread failure.
Description
An OS error occurred involving a polling thread.
Severity
Error
System Action
The program shuts down.
User Action
The program shuts down.
Component
Universal Enterprise Controller
----
UNV1098E Error creating certificate: func, errno, reason
Description
An error occurred creating the UEC's X.509 certificate. The function that encountered the error was func. The error is described by the error number errno and error reason reason.
Severity
Error
System Action
The program terminates.
User Action
Correct the condition that caused the error. If the condition cannot be determined, contact Stonebranch Customer Support.
Component
Universal Enterprise Controller
----
UNV1099E Error creating RSA key pairs: func, errno, reason
Description
An error occurred creating the UEC's RSA private and public key pair. The function that encountered the error was func. The error is described by the error number errno and error reason reason.
Severity
Error
System Action
The program terminates.
User Action
Correct the condition that caused the error. If the condition cannot be determined, contact Stonebranch Customer Support.
Component
Universal Enterprise Controller