Network Provider
Specifies the method UAG uses to communicate with the Opswise Controller. Select Opswise Message Service to connect via an OMS Server. This is the preferred communication method.
Select Opswise Transport and Message Hub to connect to the Controller using values for the Automation Center Transport and Automation Center Core. This method will be deprecated in a future release.
If no network provider is selected, the Automation Center Agent determines the method based on the connection options that are provided.
OMS Server(s)
Specifies the port and network address of an Opswise Message Service (OMS) Server that the agent will use for communication with an Opswise Controller. This value is required if the Opswise Message Service network provider is chosen in the list above.
The syntax of the value is port@host[,port@host...], where:
- port is the TCP port number on which the OMS Server is listening.
- host is the host name or IP address of the OMS Server.
If multiple servers are specified, they are separated by a comma.
Automation Center Transport(s)
Automation Center transports specifies the port and network address of Automation Center transports used for network communication. This is a required field if a network provider of Opswise Transport and Message Hub is selected.
The syntax of the value is port@host[,port@host...], where:
- port is the TCP port number on which the transport is listening.
- host is the host name or IP address of the transport. If multiple transports are specified, they are separated by a comma.
Automation Center Core
Automation Center core specifies the queue name for the Automation Center message hub. This is a required field if a network provider of Opswise Transport and Message Hub is selected.