Starting an Event-Driven UEM Server

Anchor
103374010337601033740
1033760
There are two ways start an event-driven UEM Server (uems) component:

  1. Recycle the ubroker daemon (Universal Broker service under Windows).
  2. Use Universal Control to start the uems, either locally on the server or from the mainframe.

Anchor
103374310337631033743
1033763
In this example, uems is started from the mainframe.

...

Anchor
1133954
1133954

Option

Description

-host

TCP/IP host name of the remote computer on which Universal Broker is running and accepting connections.

-encrypted

Encrypted command file.

-port

TCP/IP port number of the remote computer on which Universal Broker is running and accepting connections.

-start

Instruction to a Universal Broker to start the UEM Server.

Components

Anchor
103746010376601037460
1037660
Universal Control

Universal Event Monitor Server for Windows

Universal Event Monitor Server for UNIX

Anchor
103745010376501037450
1037650