Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

Description

The TRACKING_INTERVAL option specifies the frequency with which the UEM Server will test for the completion of a tracked event occurrence.

The test for completeness depends upon the type of event that the tracked occurrence represents. For example, an occurrence tracked for an event with an EVENT_TYPE of FILE is considered complete when two consecutive checks on a file's size return the same value.

Usage

Specification Method

Parameter / Value

IBM i

HP NonStop

UNIX

Windows

z/OS

Command Line, Short Form

n/a

Command Line, Long Form

-tracking_int seconds

(tick)

(tick)

Definition File Keyword

tracking_int seconds

(tick)

(tick)

Value

seconds is the frequency (in seconds) with which the UEM Server tests for completion of a tracked occurrence.

If TRACKING_INTERVAL is not used, the specified (or default) value of the UEM Server TRACKING_INTERVAL option is used.

  • No labels