UAG1100-UAG1199

----

UAG1100W Waiting for synchronization with Primary UAG.


Description


A Secondary UAG has started and is waiting for a Primary UAG to contact it. Once it does, the two will synchronize and the Secondary will start processing.


Severity


Warning


System Action


Processing will not start until a Primary contacts this UAG.


User Action


If not already done, start the Primary UAG.


Component

Universal Automation Center Agent


----

UAG1101I Synchronization with Primary UAG uagnm on system sysname complete.


Description


A Secondary UAG has finished synchronizing with the indicated Primary UAG on the indicated system. Processing on the Secondary will now start.


Severity


Informational


System Action


Processing will start.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1102W High common storage usage has exceeded pct percent.


Description


High common storage usage has exceeded the indicated percentage. If the percentage indicated is 100%, job tracking data has been lost.


Severity


Warning


System Action


Processing continues.


User Action


Increase the amount of high common storage that can be used by UAG. The maximum amount of high common storage is controlled by the ->

high_common_storage configuration parameter.


Component

Universal Automation Center Agent


----

UAG1103I High common storage usage is now below pct percent.


Description


High common storage usage, which had previously exceeded a high water mark, is now below the indicated percentage.


Severity


Informational


System Action


Processing continues.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1104W Unable to acquire requested number of Secondary licenses (ct1). ct2 licenses acquired.


Description


The agent was unable to acquire the number of licenses requested. Some Secondary agents might not be able to start.


Severity


Warning


System Action


Processing continues.


User Action


If more licenses are required, contact Stonebranch Inc. for additional licenses.


Component

Universal Automation Center Agent


----

UAG1105W Number of Secondary licenses received (ct1) is not sufficient for all active Secondary agents (ct1).


Description


The agent received new license information. The new number of licenses is not sufficient to support all currently active Secondary agents.


Severity


Warning


System Action


Processing continues.


User Action


If more licenses are required, contact Stonebranch Inc. for additional licenses.


Component

Universal Automation Center Agent


----

UAG1106E XCF has issued an event event for structure name. Agent is disconnecting.


Description


The agent received either an EEPLLOSSCONN, EEPLSTRFAILURE or EEPLXESRECOMMENDACTION event for the indicated structure. In all cases, the agent will disconnect from the structure. If the agent is a Secondary agent, it will also shut down.


Severity


Error


System Action


The agent will disconnect from the structure. In the case of a Secondary agent, it will shut down. A Primary agent will continue processing local jobs only.


User Action


Investigate the reason for the structure failure.


Component

Universal Automation Center Agent


----

UAG1107E UAG could not acquire a license from the Primary agent. Shutting down.


Description


UAG requested a license from the Controller through the Primary agent. Either the Primary agent or the Controller refused the request.


Severity


Error


System Action


UAG will shut down.


User Action


If more licenses are required, contact Stonebranch Inc. for additional licenses.


Component

Universal Automation Center Agent


----

UAG1108W XCF has issued an event event for Sysplex group group.


Description


The agent received either an GESYSGON, GESYSDM, GESYSDG or GESYSPRT event for the indicated XCF group. Some agents might be unavailable.


Severity


Warning


System Action


In the case of event GESYSPRT, the agent will disconnect from the XCF group. the agent will continue processing, but might be in a diminished state.


User Action


Investigate the reason for the XCF event.


Component

Universal Automation Center Agent


----

UAG1109W XCF structure name is temporarily unavailable.


Description


The agent received a system event notifying it that the named structure is temporarily unavailable. This is probably due to a system managed rebuild or

alter process having started.


Severity


Warning


System Action


The agent will wait for the structure to become available. While it is waiting, no remote job tracking data will be read or written.


User Action


If this event is unexpected, investigate the reason for the XCF event.


Component

Universal Automation Center Agent


----

UAG1110I XCF structure name is now available.


Description


The agent received a system event notifying it that the named structure is now available. This is probably due to a system managed rebuild or alter

process having finished.


Severity


Informational


System Action


The agent will resume processing remote tracking data.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1111W XCF structure name usage has exceeded pct percent.


Description


The XCF structure has exceeded the indicated percentage used.


Severity


Warning


System Action


Processing continues.


User Action


When the usage reaches 100%, tracking data will be lost. If this warning occurs frequently, it might be necessary to increase the size allocation of the structure.


Component

Universal Automation Center Agent


----

UAG1112I XCF structure name usage is now below pct percent.


Description


XCF structure usage had previously exceeded the warning threshold. It is now again below the indicated percentage.


Severity


Informational


System Action


Processing continues.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1113E XCF structure name has reached maximum capacity.


Description


The XCF structure has no room for additional data. This message indicates tracking data has been lost.


Severity


Error


System Action


Processing continues.


User Action


Tracking data has been lost. To prevent this happening in the future, increase the size allocation of the structure.


Component

Universal Automation Center Agent


----

UAG1114E Message could not be sent to dest. id/pm>.


Description


A message could not be sent to the indicated recipient. Tracking data has likely been lost.


Severity


Error


System Action


Processing continues.


User Action


This will likely result in an event or task not moving to its next state. If an execid is provided, it can be matched to a task and its state can be verified.


Component

Universal Automation Center Agent


----

UAG1115E Error obtaining write lock on Extension module 'fname': func, errno, reason


Description


An error occurred opening write lock on the specified Universal Extension module file named fname. The function func failed with error code errno, which is described by reason.


Severity


Error


System Action


UAG continues processing.


User Action


Correct the error condition and restart UAG. Contact Stonebranch Customer Support if assistance if required.


Component

Universal Automation Center Agent


----

UAG1116E Error initializing Extension Manager: func, errno, reason


Description


An error occurred while initializing the Extension Manager module. The function func failed with error code errno, which is described by reason.


Severity


Error


System Action


UAG continues processing. However, Universal Extension tasks will go to Start Failure.


User Action


Correct the error condition and restart UAG. Contact Stonebranch Customer Support if assistance if required.


Component

Universal Automation Center Agent


----

UAG1117W Universal Extension services are unavailable.


Description


Due to errors that occurred while initializing the Extension Manager module. Universal Extension task services are not available.


Severity


Warning


System Action


UAG continues processing. However, Universal Extension tasks will go to Start Failure.


User Action


Correct the error condition and restart UAG. Contact Stonebranch Customer Support if assistance if required.


Component

Universal Automation Center Agent


----

UAG1118I Initializing Extension Manager...


Description


Initialization of the Extension Manager is beginning.


Severity


Informational


System Action


Processing continues.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1119I Extension Manager initialization complete.


Description


Initialization of the Extension Manager is finished.


Severity


Informational


System Action


Processing continues.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1120I A Primary agent with system ID 'sid' is already running.


Description


A Primary agent is already running with the same system identifier. Only one Sysplex Primary agent can be active for each system identifier.


Severity


Informational


System Action


Depending on the configuration, the agent will either start as a Secondary agent, or the agent might shut down.


User Action


If this condition is expected, nothing. If the intention is to run another agent, configure each one with a unique system identifier. Else, configure this agent to run as a Secondary agent.


Component

Universal Automation Center Agent


----

UAG1121I Switch to Sysplex mode mode complete.


Description


An agent has completed the switch from Sysplex Secondary to Primary mode or from Primary to Secondary mode.


Severity


Informational


System Action


Processing continues.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1122E Switch to Sysplex mode mode could not be completed. Reason: rsn.


Description


An agent could not complete the Sysplex mode switch for the indicated reason.


Severity


Error


System Action


Depending on the error encountered, processing might continue in the original mode, or end.


User Action


Investigate the reason for the failure.


Component

Universal Automation Center Agent


----

UAG1123E Error refreshing Extension Manager: func, errno, reason


Description


An error occurred while refreshing the Extension Manager module. The function func failed with error code errno, which is described by reason.


Severity


Error


System Action


UAG continues processing. However, Universal Extension tasks will go to Start Failure.


User Action


Correct the error condition and restart UAG. Contact Stonebranch Customer Support if assistance if required.


Component

Universal Automation Center Agent


----

UAG1124I Refreshing Extension Manager...


Description


Extension Manager has started to process a configuration refresh.


Severity


Informational


System Action


Processing continues.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1125I Extension Manager refresh complete.


Description


Refresh of the Extension Manager has finished.


Severity


Informational


System Action


Processing continues.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1126I This Agent will start as a Secondary.


Description


A Primary agent is already running with the same system identifier. Since this agent is configured as Primary/Secondary, it will start as a Secondary agent.


Severity


Informational


System Action


Processing continues.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1127I This Agent will request to take over as Primary.


Description


A Primary agent is already running with the same system identifier. Since this agent is configured as Always Primary, it will request to take over as Primary agent.


Severity


Informational


System Action


Processing continues.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1128W Request to take over as Primary declined.


Description


Another agent has requested to take over as Primary agent. Since this agent is configured as Always Primary, the request has been declined.


Severity


Warning


System Action


Processing continues.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1129E Unable to take over as Primary agent. Agent is shutting down.


Description


This agent had requested to take over as Primary agent. The request has been declined by the current Primary agent.


Severity


Error


System Action


This agent will shut down.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1130I Agent on system system requests this agent to switch to Secondary.


Description


This agent has been requested to switch to Secondary mode by the agent on the indicated system.


Severity


Informational


System Action


This agent will switch to Secondary mode.


User Action


None.


Component

Universal Automation Center Agent


----

UAG1131W WARNING: Agent name is connected with a mismatched system ID of ID.


Description


An agent is connected to the XCF structure being used by this agent. The agent is using a different system ID from this agent. This will create issues with tracking workload in the Sysplex.


Severity


Warning


System Action


Processing continues.


User Action


Update the configuration to prevent agents with different system IDs connecting to the same XCF structure.


Component

Universal Automation Center Agent


----

UAG1132E Error formatting the JCL to execute UFTP (errno): reason


Description


The JCL needed to execute the Universal Agent FTP client, UFTP, on behalf of a File Transfer or Remote File Monitor task could not be generated. errno is the error number and reason is an explanation of the error.


Severity


Error


System Action


The File Transfer or Remote File Monitor task will fail to execute.


User Action


Examine the JCL submitted to JES to identify which statement failed to

get formatted properly. If possible, change the values specified on the

task form to correct the formatting error. Otherwise, contact

Stonebranch customer support for assistance.


Component

Universal Automation Center Agent


----

UAG1133E Keyword kw: Invalid character 'c1' found in position %u. 'c2/pm>' expected.


Description


An invalid character was found while parsing the value of a keyword.


Severity


Error


System Action


The product will fail to initalize.


User Action


Examine the keyword value and correct any discrepancies.


Component

Universal Automation Center Agent


----

UAG1134E Invalid value for keyword kw. One of 'c1' expected.


Description


An invalid value was found for a keyword.


Severity


Error


System Action


The product will fail to initalize.


User Action


Examine the keyword value and correct any discrepancies.


Component

Universal Automation Center Agent


----

UAG1135W An error occurred processing message nsg.


Description


An error occurred while processing the indicated message.


Severity


Warning


System Action


Processing continues.


User Action


Look for additional messages to provide further information.


Component

Universal Automation Center Agent