UAG1100-UAG1199
----
UAG1100W Waiting for synchronization with Primary UAG.
Description
A Secondary UAG has started and is waiting for a Primary UAG to contact it. Once it does, the two will synchronize and the Secondary will start processing.
Severity
Warning
System Action
Processing will not start until a Primary contacts this UAG.
User Action
If not already done, start the Primary UAG.
Component
Universal Automation Center Agent
----
UAG1101I Synchronization with Primary UAG uagnm on system sysname complete.
Description
A Secondary UAG has finished synchronizing with the indicated Primary UAG on the indicated system. Processing on the Secondary will now start.
Severity
Informational
System Action
Processing will start.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1102W High common storage usage has exceeded pct percent.
Description
High common storage usage has exceeded the indicated percentage. If the percentage indicated is 100%, job tracking data has been lost.
Severity
Warning
System Action
Processing continues.
User Action
Increase the amount of high common storage that can be used by UAG. The maximum amount of high common storage is controlled by the ->
high_common_storage configuration parameter.
Component
Universal Automation Center Agent
----
UAG1103I High common storage usage is now below pct percent.
Description
High common storage usage, which had previously exceeded a high water mark, is now below the indicated percentage.
Severity
Informational
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1104W Unable to acquire requested number of Secondary licenses (ct1). ct2 licenses acquired.
Description
The agent was unable to acquire the number of licenses requested. Some Secondary agents might not be able to start.
Severity
Warning
System Action
Processing continues.
User Action
If more licenses are required, contact Stonebranch Inc. for additional licenses.
Component
Universal Automation Center Agent
----
UAG1105W Number of Secondary licenses received (ct1) is not sufficient for all active Secondary agents (ct1).
Description
The agent received new license information. The new number of licenses is not sufficient to support all currently active Secondary agents.
Severity
Warning
System Action
Processing continues.
User Action
If more licenses are required, contact Stonebranch Inc. for additional licenses.
Component
Universal Automation Center Agent
----
UAG1106E XCF has issued an event event for structure name. Agent is disconnecting.
Description
The agent received either an EEPLLOSSCONN, EEPLSTRFAILURE or EEPLXESRECOMMENDACTION event for the indicated structure. In all cases, the agent will disconnect from the structure. If the agent is a Secondary agent, it will also shut down.
Severity
Error
System Action
The agent will disconnect from the structure. In the case of a Secondary agent, it will shut down. A Primary agent will continue processing local jobs only.
User Action
Investigate the reason for the structure failure.
Component
Universal Automation Center Agent
----
UAG1107E UAG could not acquire a license from the Primary agent. Shutting down.
Description
UAG requested a license from the Controller through the Primary agent. Either the Primary agent or the Controller refused the request.
Severity
Error
System Action
UAG will shut down.
User Action
If more licenses are required, contact Stonebranch Inc. for additional licenses.
Component
Universal Automation Center Agent
----
UAG1108W XCF has issued an event event for Sysplex group group.
Description
The agent received either an GESYSGON, GESYSDM, GESYSDG or GESYSPRT event for the indicated XCF group. Some agents might be unavailable.
Severity
Warning
System Action
In the case of event GESYSPRT, the agent will disconnect from the XCF group. the agent will continue processing, but might be in a diminished state.
User Action
Investigate the reason for the XCF event.
Component
Universal Automation Center Agent
----
UAG1109W XCF structure name is temporarily unavailable.
Description
The agent received a system event notifying it that the named structure is temporarily unavailable. This is probably due to a system managed rebuild or
alter process having started.
Severity
Warning
System Action
The agent will wait for the structure to become available. While it is waiting, no remote job tracking data will be read or written.
User Action
If this event is unexpected, investigate the reason for the XCF event.
Component
Universal Automation Center Agent
----
UAG1110I XCF structure name is now available.
Description
The agent received a system event notifying it that the named structure is now available. This is probably due to a system managed rebuild or alter
process having finished.
Severity
Informational
System Action
The agent will resume processing remote tracking data.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1111W XCF structure name usage has exceeded pct percent.
Description
The XCF structure has exceeded the indicated percentage used.
Severity
Warning
System Action
Processing continues.
User Action
When the usage reaches 100%, tracking data will be lost. If this warning occurs frequently, it might be necessary to increase the size allocation of the structure.
Component
Universal Automation Center Agent
----
UAG1112I XCF structure name usage is now below pct percent.
Description
XCF structure usage had previously exceeded the warning threshold. It is now again below the indicated percentage.
Severity
Informational
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1113E XCF structure name has reached maximum capacity.
Description
The XCF structure has no room for additional data. This message indicates tracking data has been lost.
Severity
Error
System Action
Processing continues.
User Action
Tracking data has been lost. To prevent this happening in the future, increase the size allocation of the structure.
Component
Universal Automation Center Agent
----
UAG1114E Message could not be sent to dest. id/pm>.
Description
A message could not be sent to the indicated recipient. Tracking data has likely been lost.
Severity
Error
System Action
Processing continues.
User Action
This will likely result in an event or task not moving to its next state. If an execid is provided, it can be matched to a task and its state can be verified.
Component
Universal Automation Center Agent
----
UAG1115E Error obtaining write lock on Extension module 'fname': func, errno, reason
Description
An error occurred opening write lock on the specified Universal Extension module file named fname. The function func failed with error code errno, which is described by reason.
Severity
Error
System Action
UAG continues processing.
User Action
Correct the error condition and restart UAG. Contact Stonebranch Customer Support if assistance if required.
Component
Universal Automation Center Agent
----
UAG1116E Error initializing Extension Manager: func, errno, reason
Description
An error occurred while initializing the Extension Manager module. The function func failed with error code errno, which is described by reason.
Severity
Error
System Action
UAG continues processing. However, Universal Extension tasks will go to Start Failure.
User Action
Correct the error condition and restart UAG. Contact Stonebranch Customer Support if assistance if required.
Component
Universal Automation Center Agent
----
UAG1117W Universal Extension services are unavailable.
Description
Due to errors that occurred while initializing the Extension Manager module. Universal Extension task services are not available.
Severity
Warning
System Action
UAG continues processing. However, Universal Extension tasks will go to Start Failure.
User Action
Correct the error condition and restart UAG. Contact Stonebranch Customer Support if assistance if required.
Component
Universal Automation Center Agent
----
UAG1118I Initializing Extension Manager...
Description
Initialization of the Extension Manager is beginning.
Severity
Informational
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1119I Extension Manager initialization complete.
Description
Initialization of the Extension Manager is finished.
Severity
Informational
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1120I A Primary agent with system ID 'sid' is already running.
Description
A Primary agent is already running with the same system identifier. Only one Sysplex Primary agent can be active for each system identifier.
Severity
Informational
System Action
Depending on the configuration, the agent will either start as a Secondary agent, or the agent might shut down.
User Action
If this condition is expected, nothing. If the intention is to run another agent, configure each one with a unique system identifier. Else, configure this agent to run as a Secondary agent.
Component
Universal Automation Center Agent
----
UAG1121I Switch to Sysplex mode mode complete.
Description
An agent has completed the switch from Sysplex Secondary to Primary mode or from Primary to Secondary mode.
Severity
Informational
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1122E Switch to Sysplex mode mode could not be completed. Reason: rsn.
Description
An agent could not complete the Sysplex mode switch for the indicated reason.
Severity
Error
System Action
Depending on the error encountered, processing might continue in the original mode, or end.
User Action
Investigate the reason for the failure.
Component
Universal Automation Center Agent
----
UAG1123E Error refreshing Extension Manager: func, errno, reason
Description
An error occurred while refreshing the Extension Manager module. The function func failed with error code errno, which is described by reason.
Severity
Error
System Action
UAG continues processing. However, Universal Extension tasks will go to Start Failure.
User Action
Correct the error condition and restart UAG. Contact Stonebranch Customer Support if assistance if required.
Component
Universal Automation Center Agent
----
UAG1124I Refreshing Extension Manager...
Description
Extension Manager has started to process a configuration refresh.
Severity
Informational
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1125I Extension Manager refresh complete.
Description
Refresh of the Extension Manager has finished.
Severity
Informational
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1126I This Agent will start as a Secondary.
Description
A Primary agent is already running with the same system identifier. Since this agent is configured as Primary/Secondary, it will start as a Secondary agent.
Severity
Informational
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1127I This Agent will request to take over as Primary.
Description
A Primary agent is already running with the same system identifier. Since this agent is configured as Always Primary, it will request to take over as Primary agent.
Severity
Informational
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1128W Request to take over as Primary declined.
Description
Another agent has requested to take over as Primary agent. Since this agent is configured as Always Primary, the request has been declined.
Severity
Warning
System Action
Processing continues.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1129E Unable to take over as Primary agent. Agent is shutting down.
Description
This agent had requested to take over as Primary agent. The request has been declined by the current Primary agent.
Severity
Error
System Action
This agent will shut down.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1130I Agent on system system requests this agent to switch to Secondary.
Description
This agent has been requested to switch to Secondary mode by the agent on the indicated system.
Severity
Informational
System Action
This agent will switch to Secondary mode.
User Action
None.
Component
Universal Automation Center Agent
----
UAG1131W WARNING: Agent name is connected with a mismatched system ID of ID.
Description
An agent is connected to the XCF structure being used by this agent. The agent is using a different system ID from this agent. This will create issues with tracking workload in the Sysplex.
Severity
Warning
System Action
Processing continues.
User Action
Update the configuration to prevent agents with different system IDs connecting to the same XCF structure.
Component
Universal Automation Center Agent
----
UAG1132E Error formatting the JCL to execute UFTP (errno): reason
Description
The JCL needed to execute the Universal Agent FTP client, UFTP, on behalf of a File Transfer or Remote File Monitor task could not be generated. errno is the error number and reason is an explanation of the error.
Severity
Error
System Action
The File Transfer or Remote File Monitor task will fail to execute.
User Action
Examine the JCL submitted to JES to identify which statement failed to
get formatted properly. If possible, change the values specified on the
task form to correct the formatting error. Otherwise, contact
Stonebranch customer support for assistance.
Component
Universal Automation Center Agent
----
UAG1133E Keyword kw: Invalid character 'c1' found in position %u. 'c2/pm>' expected.
Description
An invalid character was found while parsing the value of a keyword.
Severity
Error
System Action
The product will fail to initalize.
User Action
Examine the keyword value and correct any discrepancies.
Component
Universal Automation Center Agent
----
UAG1134E Invalid value for keyword kw. One of 'c1' expected.
Description
An invalid value was found for a keyword.
Severity
Error
System Action
The product will fail to initalize.
User Action
Examine the keyword value and correct any discrepancies.
Component
Universal Automation Center Agent
----
UAG1135W An error occurred processing message nsg.
Description
An error occurred while processing the indicated message.
Severity
Warning
System Action
Processing continues.
User Action
Look for additional messages to provide further information.
Component
Universal Automation Center Agent