INACTIVE_DATE_TIME - UEM Manager configuration option
Description
The INACTIVE_DATE_TIME option specifies the date and time at which the UEM Server will stop testing for new occurrences of the specified system event. This is also the date and time by which any event occurrences detected by the UEM Server must complete in order for those occurrences to move into a triggered state.
If a detected event occurrence does not complete by this date and time, UEM will set that occurrence to a rejected state. If the specified date and time elapses, and no occurrence of the specified system event was detected by UEM, the event will be set to an expired state.
When the inactive date and time elapses, the UEM Server will wait for any executing handler processes to finish, and then end. When the UEM Server ends, the UEM Manager also will end at this time if it was instructed to wait for the Server by the WAIT option.