MESSAGE_LEVEL - UEM Manager configuration option

Description

The MESSAGE_LEVEL option controls which messages are issued by a UEM Manager.

Optionally, it also allows a date and time stamp to be included with each message.

Usage

Method

Syntax

IBM i

HP NonStop

UNIX

Windows

z/OS

Command Line, Short Form

-l level [,time]

(tick)

(tick)

(tick)

Command Line, Long Form

-level level [,time]

(tick)

(tick)

(tick)

Environment Variable

UEMLEVEL=level [,time]

(tick)

(tick)

Configuration File Keyword

message_level level [,time]

(tick)

(tick)

(tick)

Value

level is the type of messages issued.

Valid values for level are:

  • trace
    Issues trace messages to the data set referenced by the UNVTRACE DD statement (for z/OS) or to a file that resides in the UEM Manager working directory named uem.trc (for Windows and UNIX).

Note

trace is used for debugging purposes only. It should be used only when requested by Stonebranch Inc. Customer Support.

  • audit
    Issues audit, informational, warning, and error messages.
  • info
    Issues informational, warning and error messages.
  • warn
    Issues warning and error messages.
  • error
    Issues error messages only.

Default

UNIX

warn

Windows

warn

z/OS

info




time specifies whether or not a date and time stamp is to be included with each message.

Valid values for time are:

  • time
    Include a date and time stamp with each message.
  • notime
    Do not include a date and time stamp with each message.

Default

UNIX

notime

Windows

notime

z/OS

time