TRACKING_INTERVAL - UEM Manager configuration option
Description
The TRACKING_INTERVAL option specifies the frequency with which the UEM Server will test for the completion of a tracked event occurrence.
The test for completeness depends upon the type of event that the tracked occurrence represents. For example, an occurrence tracked for an event with an EVENT_TYPE of FILE is considered complete when two consecutive checks on a file's size return the same value.
Usage
Method |
Syntax |
IBM i |
HP NonStop |
UNIX |
Windows |
z/OS |
Command Line, Short Form |
n/a |
|
|
|
|
|
Command Line, Long Form |
-tracking_int seconds |
|
|
|
|
|
Environment Variable |
n/a |
|
|
|
|
|
Configuration File Keyword |
n/a |
|
|
|
|
|
Value
seconds is the frequency (in seconds) with which the UEM Server tests for completion of a tracked occurrence.
If TRACKING_INTERVAL is not used, the specified (or default) value of the UEM Server TRACKING_INTERVAL option is used.