UNV0200-UNV0299
----
UNV0202E Cannot access spool directory 'dir': reason
Description
The spool directory, used to store the broker database files, could not be accessed. dir is the complete path name of the spool directory. reason is an explanation of the error.
Severity
Error
System Action
The program terminates.
User Action
Make sure the directory exists and the user account running the ubroker program has access to this directory.
Component
Universal Broker
----
UNV0203E Error opening or creating X.509 certificate: func, rtnCode, locus, type, message.
Description
An error occurred when the Broker attempted to open or create the Broker's SSL server certificate. If the Broker is not configured with a certificate, then it was attempting to create an internal certificate. The information provided in the message can help Stonebranch Support to diagnose the problem. The information provided consists of the function that failed, func, the function's return code, rtnCode, the error locus, locus, the error type, type, and the error message, message.
Severity
Error
System Action
The program terminates.
User Action
Contact Stonebranch Customer Support for assistance in resolving the problem.
Component
Universal Broker
----
UNV0204E Error creating the public and private keys: func, rtnCode, message.
Description
An error occurred when the Broker attempted to create its public and private keys used for its internal X.509 SSL server certificate. The information provided in the message can help Stonebranch Support to diagnose the problem. The information provided consists of the function that failed, func, the function's return code, rtnCode, the error message, message.
Severity
Error
System Action
The program terminates.
User Action
Contact Stonebranch Customer Support for assistance in resolving the problem.
Component
Universal Broker
----
UNV0205E Component definition 'compname' specifies restart but it is not an auto-start component.
Description
The configuration_file entry in the definition file for the component identified by compname has set the RESTART option to YES but the component is not an auto-start component. The restart facility is only available for auto-start components.
Severity
Error
System Action