Universal Configuration Manager - Universal Event Monitor Server
Universal Event Monitor Server
Universal Event Monitor Server: Message Options
Field | Description |
|---|---|
Message Level | Error |
Universal Event Monitor Server: Server Options
Field | Description |
|---|---|
User Security Options for handling Execution | Require user ID and password to start process |
Polling Interval | Specifies the frequency with which UEM Server will check (and update, if necessary) the active or inactive state of an enabled event definition. For those events that are active, any new occurrences of system events will also be detected at this time. |
Universal Event Monitor Server: Network Options
Field | Description |
|---|---|
Keep alive interval | This value specifies the frequency with which a demand driven UEM Server sends a keep alive message to the Universal Event Monitor Manager. This message ensures that the control session between the UEM Manager and Server remains open even when there is no monitoring activity or other information to send across that connection. |
Code Page | Sets the translation table used to translate text-based data transmitted across the network. |
Universal Event Monitor Server: Event Options
Field | Description |
|---|---|
Default Event Handler Options | If no triggered handler is specified, use the following |
Default Component Name | Specifies the event driven UEM Server component (that is, those components with a component type of "uems") to which an event will be assigned if no component name is specified when the event definition is created. When this event driven UEM Server component starts, it will load and monitor those events that have been assigned to it. An event may not be assigned to a demand-driven UEM Server component (that is, those components with a component type of "uemd"), and only event-driven UEM Server components are listed here. |
Tracking interval | Specifies the frequency with which a tracked event occurrence will be tested for completeness, if no such value is provided in the event definition. A value of 0 indicates that an event occurrence will not be tracked, and will be tested for completeness as soon as the occurrence is detected by UEM Server. |
Set event-specific options | Lists the types of events supported by UEM Server. Default configuration options that are specific to the selected event type may be updated by selecting the Edit... button. |
Edit Button | Displays a dialog from which configuration options that are specific to the selected event type may be updated.
Minimum file size |