Property |
| UI Field Name | Description | Specifications | Required |
---|
| Expiration Action | Expiration Action to specify the timeout Execution status. | Valid values: As String = Failed, As Value = 1 As String = Finished, As Value = 2
Default is Failed (1). | N |
|
|
| Time Limit | If valueMonitorType is Change or Current/Change; Used for Variable Monitor tasks not associated with a trigger; Amount of time (in units specified by timeLimitUnit ) to monitor for the Variable Monitor conditions to be met. | The timeLimit duration is always relative to the start time of the Variable Monitor task instance. | N |
|
| Time Limit Unit | Unit of time to use for timeLimit . | Valid Values: - As String = Minutes, As Value = 2
- As String = Hours, As Value = 3
- As String = Days, As Value = 4
Default is Hours (3). | N |
|
| Value | If valueCondition is =, !=, >, >=, <, <=, or regex; Value of the variable being monitored. |
| N |
|
| Value Condition | Condition for the value of the variable being monitored. | Valid values: - As String = -- None --, As Value = 0
- As String = =, As Value = 1
- As String = !=, As Value = 2
- As String = >, As Value = 3
- As String = >=, As Value = 4
- As String = <, As Value = 5
- As String = <=, As Value = 6
- As String = regex, As Value = 7
- As String = undefined, As Value = 8
Default is = (1) | N |
|
| Value Monitor Type | Type of monitoring to be done on the Variable value. | Valid values: - As String = Current, As Value = 1
- As String = Change, As Value = 2
- As String Current/Change, As Value = 3
Default is Current (1). | N |
|
| Variable to Monitor | Name of the variable to monitor. | Variables are supported. | Y |